HARRY J. BOSWORTH COMPANY 7227 North Hamlin Avenue Skokie, Illinois 60076-3999 Information Phone: 847.679.3400 Emergency Phone: 800.535.5053
PRODUCT: Trim/Trim™ II/Trim™ Tints/Trim™ VW Powders Hazardous Components Physical/Chemical Characteristics
4. Cadmium pigments 6. Mineral pigment 4. N/A
4. Cadmium pigments 6. Mineral pigment 4. 7440-43-9
Reactivity Data Fire and Explosion Hazard Data
Methyl methacrylate monomers and oxides of carbon
Avoid extinguishing methods which may generate dust clouds.
Water stream can disperse dust into air, producing a fire hazard and possible explosion hazard if exposed to ignition source.
Polymer dust is combustible. The explosive limits of the
polymer particles suspended in air are approximately those of coal dust. Fire fighters should wear self-contained breathing apparatus.
Health Hazard Data Emergency and First Aid Procedures
California Proposition 65 Warning: This product
Immediately flush eyes with water, contact physician.
may contain a chemical known to the state of
Effects and Hazards of Overexposure (Acute and Chronic) Precautions for Safe Handling and Use
EFFECTS AND HAZARDS OF INHALATION (BREATHING):
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED:
Sweep up with sweeping compound. Avoid dusting.
EFFECTS AND HAZARDS OF INGESTION (SWALLOWING):
May be disposed of in landfill or incinerated. Follow Federal,
state and local regulations for disposal.
PRECAUTIONS TO BE TAKEN IN HANDLING AND
Handle with care. Store in cool, dry place. Keep container
closed to prevent water absorption and contamination.
This product is for professional use only as stated in directions.
It is the responsibility of the dentist to train personnel.
Control Measures Additional Information
Use type for particulates not otherwise classified, if needed.
This MSDS was prepared in accordance with the requirements of
the OSHA Hazard Communication Standard (29CFR 1910.1200) and is to be used only for this product. The information contained in this sheet is, to the best of our knowledge, believed to be accurate
Health Hazard Index: Ratings: Ventilation Shipping Information
To the best of our knowledge, the information contained herein is accurate. However, The
Harry J. Bosworth company does not assume any liability whatsoever for the accuracy
or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown health hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist.
Trim/Trim™ II/Trim™ Tints/Trim™ VW Powders MSDS 092
Information sur les antiplaquettaires de 3ème génération De nombreux patients que vous prenez en charge sont traités par des agents antiplaquettaires du fait de problèmes cardiovasculaires. La recherche d’un traitement par l’une de ces molécules est indispensable dans le cadre de la prévention et de la prise en charge du risque hémorragique péri opératoire. Orthorisq sou
Guru/Journal of Engineering, Science and Management Education/Vol. 2, 2010/73-77 MICROBIAL STUDIES ON SOME METAL COMPLEXES WITH TETRACYCLINE Pranay Guru* Received July 22, 2010, Revised July 23, 2010 ; Accepted Aug. 26, 2010 Abstract RESULTS AND DISCUSSIONS The present paper deals with the microbial studies of Ni(II) In general all the tested complexes showed higher toxicit